Home · Guides
Compressor air hose: 6, 8 or 10 mm and how much pressure you lose
Updated 12 Oct 2026 · GarageTally
“My impact wrench won’t undo anything” is a question that has kept coming up on Italian forums for years. In one documented case the problem was solved, among other things, with a larger hose [59]; in another, a user estimates that the compressor supplied about half the air the wrench needed [62]. The hose is the part you can check most easily.
How much you lose
Pressure lost in a smooth hose, with 6.3 bar at the compressor outlet, without fittings:
| Consumption | Hose | 6 mm | 8 mm | 10 mm |
|---|---|---|---|---|
| 200 l/min | 10 m | 0.49 bar | 0.12 bar | 0.04 bar |
| 360 l/min | 10 m | 1.62 bar | 0.35 bar | 0.11 bar |
| 360 l/min | 20 m | — | 0.72 bar | 0.23 bar |
Diameter matters much more than length: for the same air, going from 6 to 8 mm cuts the loss by a factor of about four, and from 8 to 10 mm by about three. A 360 l/min tool that needs 6.2 bar, such as the Metabo DB 10 drill [38], with 20 m of 8 mm hose would want almost 7 bar at the compressor, and at 7 bar many hobby compressors deliver less air.
Open an example in the calculator and try changing the diameter.
How we calculate it
- Loss: Darcy-Weisbach equation, with the Colebrook-White friction factor solved by iteration starting from the Swamee and Jain formula [58].
- Air at 20 °C: density 1.204 kg/m³ at atmospheric pressure, rising in proportion to the absolute pressure in the hose [55]; dynamic viscosity 18.13 µPa·s [56].
- Roughness: 0.007 mm, the upper value for smooth plastic hoses [57].
- Left out: quick couplings, coiled hoses and reducers add losses. A narrow quick coupling can lose more pressure than a few metres of hose.
Air hoses are usually labelled with the internal and the external diameter, for example 8 × 12 mm: the first number is the one that counts.
Sources
- DB 10 (604120000) Trapano ad aria compressa — Metabowerke GmbH, retrieved 11 Oct 2026
- Air Density, Specific Weight, and Thermal Expansion Coefficients at Varying Temperatures and Pressures — The Engineering ToolBox, retrieved 11 Oct 2026
- Air Viscosity: Dynamic and Kinematic Viscosity at Various Temperatures and Pressures — The Engineering ToolBox, retrieved 11 Oct 2026
- Surface Roughness Coefficients — The Engineering ToolBox, retrieved 11 Oct 2026
- Explicit equations for pipe-flow problems — Swamee P. K., Jain A. K., Journal of the Hydraulics Division, ASCE, vol. 102, n. 5, pp. 657–664, maggio 1976 (scheda TRID), retrieved 11 Oct 2026
- Compressore fiacco — PLC Forum, discussione del 14 agosto 2010, retrieved 11 Oct 2026
- Discussione su avvitatore e compressore — Motoclub Tingavert, forum tecnico, 2006–2009, retrieved 11 Oct 2026